Quick Answer: What Zone Can A Shaver Socket Go In?

Providing the Shaver socket is reduced to 110V it should go in zone 2 or preferably, zone 3, never in zone 1. Also it’s worthy to note that there should be no 240V sockets in the bathroom at all.

What zone can you fit a shaver socket?

According to the updated 17th edition of the IEE Wiring Regulations, it is safe to install electric shaver sockets in your bathroom providing the socket is 110v and installed in zone 2 or beyond, with at least a 3-metre gap from either the bath or shower. This is done to avoid any splash backs onto the socket.

Can shaver socket go in Zone 1?

Shaver sockets are becoming a common feature in bathrooms, whether they are directly installed into the wall, or they come as a feature in a mirrored cabinet. In relation to bathroom zones, shaver socket regulations state that one must be placed at least 3m horizontally from the boundary of zone 1.

You might be interested:  Often asked: What Are The Parts Of A Hinge Called?

Can shaver socket go in Zone 2?

A shaver socket-outlet with a transformer is called a shaver supply unit. A shaver supply unit complying with BS EN 61558-2-5 may be installed in zone 2 of a location containing a bath or shower (Regulation 701.512. 3 refers).

Can you run a shaver socket off a ring main?

Yes of course you can run a shaver socket from a ring final with no FCU in between.

What is bathroom Zone 1?

Bathroom Zone 1 Zone 1 is the area above the bath or shower tray to a height of 2.25m from the floor. Any fitting used in this zone must have a minimum rating of IPx4*, which means it is protected against water spray from all directions.

What IP rating is Zone 2?

Zone 2 is an area stretching 0.6m outside the perimeter of the bath and to a height of 2.25m from the floor. In these bathroom zones an IP rating of at least IP44 is required. In addition, it is good practice to consider the area around a wash basin, within a 60cm radius of any tap, to be considered as zone 2.

Where can I put a shaver socket in a bathroom?

The use or installation of sockets is not allowed in bathrooms or shower rooms unless they can be fitted at least 3 metres from the bath or shower. The only exception to this is a shaver-supply unit.

Can IPX4 be used in Zone 1?

The area stretching 0.6m outside the perimeter of the bath to a height of 2.25m. As with Zone 1, the minimum rating for this zone is IPX4.

Can I plug my toothbrush into a shaver socket?

In short, yes it will work but the socket may eventually fail. Not just toothbrushes which often take 24 hours to charge or are designed to be permanently trickle charging but rechargeable shavers too.

You might be interested:  Question: How Do You Clean Mildew Outside?

What does Zone 1 and 2 mean in bathroom lighting?

Zone 1 is the area above the bath or shower to a height of 2.25m from the floor. It’s also worth noting that most shower lights are rated at IP65 in any case. Zone 2 is an area stretching 0.6m outside the perimeter of the bath and to a height of 2.25m from the floor.

Is it illegal to have a plug socket in the bathroom UK?

Sockets. Sockets are not allowed in bathrooms or shower rooms (apart from shaver-supply units) unless they can be fitted at least three metres from the bath or shower.

Does a shaver socket need an RCD?

An RCD offers no additional protection for a shaver socket. The shaver socket has a transformer inside and the secondary winding is isolated from earth.

Why is a shaver socket allowed in a bathroom?

1 Answer. UK shaver sockets are not a lower voltage, but the ones in bathrooms include an isolating transformer and thermal cutout so that neither wire of the shaver has any voltage to earth (so a shock to earth is impossible) and the socket cannot be used for more powerful appliances.

What height should a shaver socket be?

The 450mm to 1200mm band is the generally accepted band to satisfy Part M. Or it is stated as ONE WAY of satisfying the requirements.

Written by